MB5901
Request a price
1‑Port Industrial Secure Modbus TCP/RTU/ASCII Gateway, DIN‑rail mount, wide‑temperature. Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-ofuse configuration utility provided with Modbus Gateway can quickly select the hardware interface , and easily switch to the existing communication infrastructure. Industrial EMC protection and wide temperature operation capability make MB5901…
-

MB5904D
Request a price
4‑Port Industrial Secure Modbus TCP/RTU/ASCII Gateway with optional 3kV isolation, DIN‑rail mount, dual power input, wide‑temperature. Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of use configuration utility provided with Modbus Gateway can quickly select the hardware interface , and easily switch to the existing communication infrastructure. Industrial EMC…
-

MB5904D-CT
Request a price
The ATOP MB5904D-CT is a four-port industrial secure Modbus gateway that links serial devices to Ethernet in a compact DIN-rail form factor. It converts between Modbus TCP and Modbus RTU or ASCII across four serial ports, and automatically maps every connected slave into local memory so masters can poll a single cached image rather than…
-

MB5908
Request a price
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in…
-

MB5908-CT
Request a price
The ATOP MB5908-CT is an eight-port industrial secure Modbus gateway that bridges serial field devices to Ethernet networks. It translates between Modbus TCP on the network side and Modbus RTU or ASCII on eight independent serial ports, letting PLCs, meters, RTUs and other RS-232/485 equipment share data across a modern IP infrastructure. RJ45 connectors and…
-

MB5908A
Request a price
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422(*), and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface , and easily switch to the existing communication infrastructure. Industrial EMC protection, IEC61850-3 compliance, and wide temperature operation capability render MB5908A ready for every mission. 8‑Port IEC61850‑3 Certified…
-

MB5908A-CT
Request a price
The ATOP MB5908A-CT is an eight-port, IEC 61850-3 certified industrial secure Modbus gateway built for electrical substations and other demanding power applications. It connects serial RS-232/485 field devices to Ethernet, mapping Modbus RTU and ASCII slaves onto Modbus TCP for SCADA and control systems. The rack-mount chassis offers a choice of DSub-9 or TB5 terminal-block…
-

MB5916
Request a price
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in…
-

MB5916-CT
Request a price
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in…
-

MB5916A
Request a price
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in…
-

MB5916A-CT
Request a price
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in…
-

SE5901
Request a price
The Industrial Serial Device Server SE5901 is a cost effective gateway for Ethernet (TCP/IP) and serial signal communications; allowing almost any serial device to be connected to a new or existing Ethernet network. By encapsulating serial data and transporting it over Ethernet, SE5901 offers full duplex and bi-directional data seamlessly between the serial port and…
-

SE5904D
Request a price
The Industrial Serial Device Server SE5904D is a cost effective gateway for Ethernet (TCP/IP) and serial signal communications; allowing almost any serial device to be connected to a new or existing Ethernet network. By encapsulating serial data and transporting it over Ethernet, SE5904D offers full-duplex and bi-directional data seamlessly between the four serial ports and…
-

SE5908
Request a price
The Industrial Serial Device Server SE5908 is an advance gateway for Ethernet (TCP/IP) and serial signal communications; allowing any serial device to be connected to a new or existing Ethernet network. By encapsulating serial data and transporting it over Ethernet (both copper and fiber), offers full-duplex and bi-directional data seamlessly between the four available serial…
-

SE5908A
Request a price
8‑Port IEC61850‑3 Certified Industrial Rack‑Mounted Secure Serial Device Server. The Industrial Serial Device Server SE5908A is a high-profile, high performance wide temperature gateway for Ethernet (TCP/IP) and serial signal communications; allowing almost any serial device to be connected to a new or existing Ethernet network. By encapsulating serial data and transporting it over Ethernet, it…
-

SE5916
Request a price
The Industrial Serial Device Server SE5916 is an advance gateway for Ethernet (TCP/IP) and serial signal communications; allowing any serial device to be connected to a new or existing Ethernet network. By encapsulating serial data and transporting it over Ethernet (both copper and fiber), offers full-duplex and bi-directional data seamlessly between the four available serial…
-

SE5916A
Request a price
16‑Port IEC61850‑3 Certified Industrial Rack‑Mounted Secure Serial Device Server. The Industrial Serial Device Server SE5916A is a high-profile, high performance wide temperature gateway for Ethernet (TCP/IP) and serial signal communications; allowing almost any serial device to be connected to a new or existing Ethernet network. By encapsulating serial data and transporting it over Ethernet, it…
-

SE8502
Request a price
2‑Port IP68 Waterproof Serial Server with M12 connectors, EN50155 and EN50121‑4 Railway certified. SE8502-M12 is an Industrial 2-port IP68 Serial Server, offering waterproof, dustproof, and vibration-resistant.There is a strong demand for reliable and rugged networking solutions, that can be used for the industrial workplace in harsh environmental conditions, such as high levels of moisture, dust,…
Rugged Serial & Modbus Gateway — frequently asked questions
What is the difference between a serial device server and a protocol gateway?
A serial device server tunnels raw serial data over TCP, often presenting a virtual COM port to your host software - the protocol is unchanged, it just travels over Ethernet. A protocol gateway translates between protocols, for example presenting Modbus RTU slaves as Modbus TCP registers. If your master speaks Modbus TCP you need the gateway; if an existing Windows application expects a COM port you need the device server.
Can these replace a Moxa NPort or MGate?
Functionally equivalent products exist in this range. Before swapping, confirm three things: the serial standard and wiring, the port count, and whether your host software depends on a vendor-specific virtual COM driver. That driver dependency is the usual reason a like-for-like swap fails.
How many serial ports do I need?
One per independent RS-232 or RS-422 link. RS-485 is a multidrop bus so several slaves can share one port - but total them and check the polling cycle time, because a long chain on one port slows every device on it.
Do I need isolation or surge protection?
Specify isolation where the serial run crosses between buildings, earthing systems or panels at different reference potentials, and surge protection on any run that leaves the building. The datasheet states which protection a given model includes.
Is this the same as a LoRaWAN Modbus controller?
No. These are wired devices. A LoRaWAN controller reads Modbus RTU and sends readings over radio, which is a different topology with different latency. If cabling is viable, wired is almost always the right answer.
How do I get a price?
ATOP serial gateways are quoted per project. Send us the model or the requirement with quantities and we will confirm price and lead time, typically within 14 working days.