PG5901

ATOP PG5901 Smart Grid Protocol Gateway (IEC 61850)

ATOP Technologies
Where it sits in the stack

Request a price

The ATOP PG5901 is a DIN-rail smart-grid protocol gateway with one RS-232/422/485 serial port and two 10/100BASE-T(X) RJ45 ports with RSTP. It converts between Modbus, DNP3, IEC 60870-5-101/103/104 and IEC 61850 under a front-end to back-end licence, runs from 9-48 VDC or optional 802.3af PoE, and operates from -40°C to +85°C in substations, generation plants and industrial sites.

Serial Ports1 × RS-232/422/485 (TB5 or DB9), with 2 × 10/100 RJ45 on RSTP

Add to quote

Quotes answered within one working day

Available to order · request a quote for price and lead time

Delivery & assurance

  • Ships from the UK
  • UK & EU delivery, quoted with your price
  • Pay by card or invoice
  • Manufacturer's warranty

Ships to the UK & EU · VAT invoice provided · Delivery & returns

Questions about this product? Call our UK team: 023 9223 3611

Description

The PG5901 Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different protocols Ethernet or Serial based. The serial devices communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.

1-Port RS-232/485/422 and 2× Fast Ethernet RJ45 protocol gateway. Supports DNP3.0, Modbus, IEC 60870‑5‑101/103/104 and IEC 61850 for substation/industrial smart grid integration.

PG5901 specifications

RJ45 Ports2 × 10/100BASE-T(X)
Redundancy ProtocolsRSTP on both Ethernet ports
Serial Ports1 × RS-232/422/485 (full function)
Serial InterfaceTerminal block (TB5) or DB9, chosen at order
ProtocolsModbus RTU/ASCII, Modbus TCP, DNP3 serial and TCP/IP, IEC 60870-5-101, IEC 60870-5-103 (master), IEC 60870-5-104, IEC 61850
Front-End Protocols (Slave/Server)Modbus RTU/ASCII slave, Modbus TCP server, DNP3 serial slave, DNP3 TCP/IP server, IEC 60870-5-101 slave, IEC 60870-5-104 server, IEC 61850 server
Back-End Protocols (Master/Client)Modbus master (serial) or client (TCP), DNP3 master (serial) or client (TCP/IP), IEC 60870-5-101 master, IEC 60870-5-103 master, IEC 60870-5-104 client, IEC 61850 client
Licence Combinations38 of the 48 pairs in ATOP's software table; serial-to-serial pairs (e.g. MBSS-DNSM, DNSS-01SM) are not offered on this platform; optional full licence for concurrent multi-protocol conversion
ModbusRTU/ASCII (serial) and TCP; up to 64 slaves/servers; up to 8000 points read and 4000 commands written; function codes 1, 2, 3, 4, 5, 6, 15, 16 and 43 (server side)
DNP3Level 2 and a subset of Level 3 (IEEE 1815-2012 Level 2); serial or TCP/UDP; server serves up to 5 TCP clients; client polls up to 16 IEDs; up to 8000 binary inputs, 2000 binary outputs, 4000 double inputs, 250 analogue inputs, 250 analogue outputs, 250 counters
IEC 60870-5-101Master or slave, edition 2, balanced and unbalanced modes; up to 1000 monitor points and 500 control points per data type
IEC 60870-5-104Edition 2; server serves up to 5 clients; client polls up to 10 IEDs; up to 1000 monitor points and 500 control points per data type; server event buffer up to 20,000 events
IEC 61850Client and server, Edition 1 and Edition 2, MMS (IEC 61850-8-1); 8 logical devices per port; direct and SBO control with normal or enhanced security
Time SynchronisationProtocol clock synchronisation over IEC 61850, DNP3 and IEC 60870-5-101/103/104; CP56Time2a timestamps on IEC 60870-5-104
ConfigurationWeb interface for network settings; eNode Designer for serial settings, protocol parameters and data point mapping
Input Voltage9-48 VDC; optional IEEE 802.3af PoE power input
Power Redundancy1 power input
MountingDIN-rail
Ingress ProtectionIP30
Operating Temperature-40°C to +85°C
CertificationsCE (EN 61000-6-2, EN 61000-6-4), FCC Part 15 Subpart B Class A, EN 60950-1; industrial EMC protection

Specifications taken from the manufacturer datasheet.

Which version do I need?

PG5901 is the hardware platform: one serial port with a TB5 terminal block or DB9 connector chosen at order, and optional PoE power. The protocol function is a separate software licence from ATOP's table, written front-end then back-end: the front-end is the slave or server that your SCADA, RTU or PLC master talks to, and the back-end is the master or client the gateway uses to poll field devices. For example, PG5901 with 04ES-01SM presents an IEC 60870-5-104 server to the control centre and polls an IEC 60870-5-101 outstation on the serial port as master; MBES-50EC presents a Modbus TCP server to a PLC and polls IEC 61850 IEDs as client. 38 of the table's 48 licences are offered on this platform: with one serial port, serial-to-serial pairs such as MBSS-DNSM are not. An optional full licence runs one or more protocols concurrently on both sides instead of a single pair.

Typical applications for the PG5901

  • Moving an IEC 60870-5-101 RTU onto an IEC 60870-5-104 SCADA (04ES-01SM)
  • Presenting a single Modbus RTU device to an IEC 61850 station as a server (50ES-MBSM)
  • Exposing IEC 61850 IED data to a Modbus TCP PLC (MBES-50EC)
  • PoE-powered installation in control cabinets without a separate DC supply
  • Dual-homed Ethernet on RSTP in power substations and generation plants
  • Oil and gas, farming and manufacturing sites with one legacy serial device to integrate

Complete the stack

Products that work with this one — connect it, power it, and get it online.

PG5901 — frequently asked questions

What ports does the PG5901 have?

One RS-232/422/485 serial port, ordered with a TB5 terminal block or DB9 connector, and two 10/100BASE-T(X) RJ45 Ethernet ports that support RSTP.

Which protocols and roles does it support?

Front-end (slave/server): Modbus RTU/ASCII, Modbus TCP, DNP3 serial and TCP/IP, IEC 60870-5-101, IEC 60870-5-104 and IEC 61850. Back-end (master/client): Modbus, DNP3, IEC 60870-5-101, IEC 60870-5-103, IEC 60870-5-104 and IEC 61850. ATOP's power brochure also describes a transparent function for IEC 60870-5-101 to 104 and DNP3 serial to Ethernet that converts without point mapping.

Which conversions are not available on the PG5901?

Serial-to-serial licences, such as MBSS-DNSM or DNSS-01SM, are not offered because the platform has only one serial port. For serial-to-serial conversion choose a multi-port platform such as the PG5904D.

How is the PG5901 powered, and what temperature is it rated for?

From 9-48 VDC on a single input, or optionally through IEEE 802.3af PoE. It operates from -40°C to +85°C, mounts on DIN rail and has an IP30 housing.

What is the difference between the PG5901 and the PG5904D?

The PG5904D has 4 serial ports with optional 3 kV isolation, Ethernet as 2 × RJ45 or 2 × 100/1000 SFP, two power inputs (12-48 VDC), two relay outputs and UL 61010-2-201, and it offers all 48 licences including serial-to-serial. The PG5901 has 1 serial port, 2 × 10/100 RJ45 and a single 9-48 VDC input.

What is the difference between the PG5901 and the PG5901B?

The PG5901B adds 4G LTE Cat 4 and has one 10/100/1000 RJ45 port instead of two 10/100 ports with RSTP, with an RS-232/485 serial port and a TB14 I/O version. It is rated -40°C to +70°C against the PG5901's -40°C to +85°C.

Which IEC 61850 features are implemented?

Edition 1 and Edition 2 client and server over MMS (IEC 61850-8-1), with SCL per IEC 61850-6, 8 logical devices per port, and direct or select-before-operate control with normal or enhanced security.

How much does the ATOP PG5901 Smart Grid Protocol Gateway (IEC 61850) cost in the UK?

The ATOP PG5901 Smart Grid Protocol Gateway (IEC 61850) is supplied to order and priced on application. Send a quote request and we confirm the price and lead time in writing, usually the same working day. No account is needed. Indiott is a UK distributor invoicing with VAT (PSI Technologies Ltd, VAT GB 730 2340 83).

What is the lead time and delivery cost for the ATOP PG5901 Smart Grid Protocol Gateway (IEC 61850)?

The ATOP PG5901 Smart Grid Protocol Gateway (IEC 61850) is supplied to order. We confirm the lead time in writing with your quote, before you commit to anything. UK delivery is a flat £14.25 per order ex VAT, whatever the weight or how many items you order. We ship to GB and the EU and provide a VAT invoice with every order.

Request a priceRequest a quote