UK industrial technology since 1998 Authorised Milesight distributor Ships from the UK
PG5916A

ATOP PG5916A Smart Grid Protocol Gateway (IEC 61850)

IEC 61850-3ATOP Technologies
Where it sits in the stack

Request a price

The ATOP PG5916A is a rack-mount smart-grid protocol gateway ticked for IEC 61850-3 / IEEE 1613, with sixteen RS-232/422/485 serial ports (TB5 or DB9, optional 3 kV isolation) and six Fast Ethernet ports in RJ45 or SFP versions. It offers all 48 of ATOP's Modbus, DNP3, IEC 60870-5-101/103/104 and IEC 61850 licence pairs, has two power inputs (24-48 VDC, 100-240 VAC or 100-370 VDC) and operates from -40°C to +85°C.

Serial Ports and Substation Compliance16 × RS-232/422/485 with IEC 61850-3 / IEEE 1613

Add to quote

Quotes answered within one working day

Available to order · request a quote for price and lead time

Delivery & assurance

  • Ships from the UK
  • UK & EU delivery, quoted with your price
  • Pay by card or invoice
  • Manufacturer's warranty

Ships to the UK & EU · VAT invoice provided · Delivery & returns

Questions about this product? Call our UK team: 023 9223 3611

Description

The PG5916A Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different protocols Ethernet or Serial based. The serial devices communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.

IEC 61850‑3 certified smart grid protocol gateway with high port density for substation and critical infrastructure applications.

PG5916A specifications

RJ45 Ports6 × 10/100BASE-T(X) (RJ45 version)
Fibre (SFP) Slots6 × 100BASE-X SFP (SFP version, in place of RJ45)
Redundancy ProtocolsRSTP on all 6 Ethernet ports
Serial Ports16 × RS-232/422/485 (full function)
Serial InterfaceTerminal block (TB5) or DB9, chosen at order
Serial Isolation3 kV (optional)
ProtocolsModbus RTU/ASCII, Modbus TCP, DNP3 serial and TCP/IP, IEC 60870-5-101, IEC 60870-5-103 (master), IEC 60870-5-104, IEC 61850
Front-End Protocols (Slave/Server)Modbus RTU/ASCII slave, Modbus TCP server, DNP3 serial slave, DNP3 TCP/IP server, IEC 60870-5-101 slave, IEC 60870-5-104 server, IEC 61850 server
Back-End Protocols (Master/Client)Modbus master (serial) or client (TCP), DNP3 master (serial) or client (TCP/IP), IEC 60870-5-101 master, IEC 60870-5-103 master, IEC 60870-5-104 client, IEC 61850 client
Licence CombinationsAll 48 pairs in ATOP's software table, including serial-to-serial (e.g. MBSS-DNSM, DNSS-01SM); optional full licence for concurrent multi-protocol conversion
ModbusRTU/ASCII (serial) and TCP; up to 64 slaves/servers; up to 8000 points read and 4000 commands written; function codes 1, 2, 3, 4, 5, 6, 15, 16 and 43 (server side)
DNP3Level 2 and a subset of Level 3 (IEEE 1815-2012 Level 2); serial or TCP/UDP; server serves up to 5 TCP clients; client polls up to 16 IEDs; up to 8000 binary inputs, 2000 binary outputs, 4000 double inputs, 250 analogue inputs, 250 analogue outputs, 250 counters
IEC 60870-5-104Edition 2; server serves up to 5 clients; client polls up to 10 IEDs; up to 1000 monitor points and 500 control points per data type; server event buffer up to 20,000 events
IEC 61850Client and server, Edition 1 and Edition 2, MMS (IEC 61850-8-1); 8 logical devices per port; direct and SBO control with normal or enhanced security
Time SynchronisationProtocol clock synchronisation over IEC 61850, DNP3 and IEC 60870-5-101/103/104; CP56Time2a timestamps on IEC 60870-5-104
ConfigurationWeb interface for network settings; eNode Designer for serial settings, protocol parameters and data point mapping
Input Voltage24-48 VDC, 100-240 VAC or 100-370 VDC
Power Redundancy2 power inputs
Relay Output2
MountingRack mount
Ingress ProtectionIP30
Operating Temperature-40°C to +85°C
CertificationsIEC 61850-3 / IEEE 1613, EN 61010-2-201, CE (EN 61000-6-2, EN 61000-6-4), FCC Part 15 Subpart B Class A; industrial EMC protection

Specifications taken from the manufacturer datasheet.

Which version do I need?

PG5916A hardware options: six Ethernet ports as 10/100 RJ45 or 100BASE-X SFP, serial connectors as TB5 terminal block or DB9, and optional 3 kV serial isolation. The protocol function is a separate software licence from ATOP's table, written front-end then back-end: the front-end is the slave or server that your SCADA, RTU or PLC master talks to, and the back-end is the master or client the gateway uses to poll field devices. For example, PG5916A with 50ES-03SM presents an IEC 61850 server to the station bus and polls IEC 60870-5-103 protection relays on the serial ports as master; 04ES-DNSM presents an IEC 60870-5-104 server to the control centre and polls serial DNP3 outstations as master. All 48 licences in the table are offered, including serial-to-serial pairs. An optional full licence runs one or more protocols concurrently on both sides instead of a single pair. The PG5916 is the non-A platform: RJ45 serial connectors, 2 × Ethernet, one power input, -20°C to +70°C and no IEC 61850-3 / IEEE 1613 tick.

Typical applications for the PG5916A

  • IEC 61850 substations that require IEC 61850-3 / IEEE 1613 equipment for up to 16 serial IEDs
  • Mapping IEC 60870-5-103 protection relays into an IEC 61850 station bus (50ES-03SM)
  • Presenting serial DNP3 outstations to an IEC 60870-5-104 control centre (04ES-DNSM)
  • Fibre connection to the station bus using the SFP version
  • Substation racks fed from a high-voltage DC supply (100-370 VDC input) with dual power inputs
  • Critical infrastructure retrofits where legacy serial bays stay in place

Complete the stack

Products that work with this one — connect it, power it, and get it online.

PG5916A — frequently asked questions

Is the PG5916A suitable for installation in an electricity substation?

Yes. ATOP's selection guide ticks IEC 61850-3 / IEEE 1613 for the PG5916A, and it operates from -40°C to +85°C with optional 3 kV serial isolation and two power inputs.

What is the difference between the PG5916 and the PG5916A?

The PG5916A adds IEC 61850-3 / IEEE 1613, 6 Fast Ethernet ports (RJ45 or SFP) instead of 2 RJ45, TB5 or DB9 serial connectors with 3 kV isolation instead of RJ45 with 2.5 kV, two power inputs including 100-370 VDC, two relay outputs, and -40°C to +85°C instead of -20°C to +70°C.

Can it be ordered with fibre Ethernet?

Yes. The six Ethernet ports come as 10/100BASE-T(X) RJ45 or 100BASE-X SFP versions, and all six support RSTP.

What power inputs does it accept?

24-48 VDC, 100-240 VAC or 100-370 VDC, with two power inputs and two relay outputs.

Which protocol conversions are available?

All 48 front-end/back-end licences in ATOP's table across Modbus RTU/ASCII and TCP, DNP3 serial and TCP/IP, IEC 60870-5-101, IEC 60870-5-103 (master), IEC 60870-5-104 and IEC 61850, including serial-to-serial pairs. An optional full licence runs several protocols concurrently.

Which IEC 61850 features are implemented?

Edition 1 and Edition 2 client and server over MMS (IEC 61850-8-1), SCL per IEC 61850-6, 8 logical devices per port, and direct or select-before-operate control with normal or enhanced security.

How many devices can it poll per protocol?

Up to 64 Modbus slaves or servers (8000 read points, 4000 write commands), up to 16 DNP3 IEDs, and up to 10 IEC 60870-5-104 IEDs; as a DNP3 or IEC 104 server it serves up to 5 clients.

How much does the ATOP PG5916A Smart Grid Protocol Gateway (IEC 61850) cost in the UK?

The ATOP PG5916A Smart Grid Protocol Gateway (IEC 61850) is supplied to order and priced on application. Send a quote request and we confirm the price and lead time in writing, usually the same working day. No account is needed. Indiott is a UK distributor invoicing with VAT (PSI Technologies Ltd, VAT GB 730 2340 83).

What is the lead time and delivery cost for the ATOP PG5916A Smart Grid Protocol Gateway (IEC 61850)?

The ATOP PG5916A Smart Grid Protocol Gateway (IEC 61850) is supplied to order. We confirm the lead time in writing with your quote, before you commit to anything. UK delivery is a flat £14.25 per order ex VAT, whatever the weight or how many items you order. We ship to GB and the EU and provide a VAT invoice with every order.

Request a priceRequest a quote