MB5908A-CT

ATOP MB5908A-CT Rugged Serial to Ethernet Modbus Gateway

IEC 61850-3ATOP Technologies
Where it sits in the stack

Request a price

The MB5908A-CT is an 8-port IEC 61850-3 certified rack-mount industrial secure Modbus gateway with a data concentrator that automatically maps all slaves' data into memory across up to 64 connections. It provides six Fast Ethernet interfaces (RJ45 or SFP), supports a maximum of 247 Modbus slaves, takes redundant 24-48 VDC or 100-240 VAC power, and operates from -40°C to 80°C.

Modbus data concentratorAutomatic mapping of all slaves' data into memory, up to 64 connections

Add to quote

Quotes answered within one working day

Available to order · request a quote for price and lead time

Delivery & assurance

  • Ships from the UK
  • UK & EU delivery, quoted with your price
  • Pay by card or invoice
  • Manufacturer's warranty

Ships to the UK & EU · VAT invoice provided · Delivery & returns

Questions about this product? Call our UK team: 023 9223 3611

Description

The ATOP MB5908A-CT is an eight-port, IEC 61850-3 certified industrial secure Modbus gateway built for electrical substations and other demanding power applications. It connects serial RS-232/485 field devices to Ethernet, mapping Modbus RTU and ASCII slaves onto Modbus TCP for SCADA and control systems. The rack-mount chassis offers a choice of DSub-9 or TB5 terminal-block serial connectors and dual power inputs for supply redundancy. Optional 3 kV serial isolation guards each port against surges and potential differences common in high-voltage environments. IEC 61850-3 compliance means it meets the EMC, vibration and temperature requirements for substation automation. Choose the MB5908A-CT where reliability and certification matter as much as connectivity. Browse our rugged serial and Modbus gateways.

Manufacturer datasheet (PDF)

MB5908A-CT specifications

Serial ports8 (MB5908A-CT)
Serial connectorD-Sub9 (DB models, supporting only 5-pin RS-232 mode) or 5.08mm 5-pin terminal block (TB models)
Serial modeRS-232/422/485 software selectable
Serial port isolation3 kV isolation (SiS version only; RS-422/485 only)
Baud rate1,200 ~ 921,600 bps software selectable
Data bits / stop bits5, 6, 7, 8 / 1, 2 software selectable
ParityNone, Odd, Even, Mark, Space
Flow controlNone, Xon/Xoff, RTS/CTS (RS-232 only)
Ethernet portsRJ45 x 6 (RJ45 version) or SFP x 6 (SFP version)
Ethernet speedIEEE 802.3 10BaseT; 802.3u 100BaseT(X) RJ45 version; 802.3u 100Base-FX SFP version
Modbus data concentratorAutomatic mapping of all slaves' data into memory, up to 64 connections
Modbus modesEthernet: Modbus TCP server/client (or VCOM); Serial: Modbus RTU/ASCII (master/slave)
Maximum clients/slavesModbus TCP: maximum 16 clients; maximum 247 slaves
SecurityOpenVPN client/server or IPsec VPN (peer-to-peer or peer-to-side) up to 37.9Mbps throughput, PPTP, SMTP/TLS
Redundancy protocol802.1D-2004 RSTP
Input voltageRedundant 24-48 VDC or redundant 100-240 VAC / 100-370 VDC (HV series)
Input current0.73 A @ 24 VDC; 0.35 A @ 100 VAC; 0.20 A @ 100 VDC
Power consumptionApproximately 20 W
Power redundancyYes
Power connector10-Pin Terminal Block
HousingIP30 SPCC housing
Dimensions (W x H x D)440.6 x 44 x 309 mm (1U rack-mount)
Weight4 kg
Installation19" rack mount (rack-mount kit included)
Operating temperature-40°C~80°C (-40°F~176°F)
Storage temperature-40°C~85°C
Ambient relative humidity5%~95%, 55°C (non-condensing)
SafetyEN61010-1, EN 61010-2-201
Substation complianceIEC 61850-3 / IEEE 1613
Warranty5 years

Specifications taken from the manufacturer datasheet.

Which version do I need?

This document covers the 8-port MB5908A-CT and the 16-port MB5916A-CT; the figures here are the 8-port MB5908A-CT. Part numbers are quoted by ATOP headquarters. Variants: MB5908A CT (DB9 serial), MB5908A-TB CT (terminal block), MB5908A-Sis CT (3 kV isolation, terminal block), the -6SFP equivalents with six SFP slots instead of six RJ45 ports, and -HV versions for redundant 100-240 VAC / 100-370 VDC input. Note that the 3 kV isolated version supports RS-422/485 only, and DB models support only 5-pin RS-232 mode.

Typical applications for the MB5908A-CT

  • IEC 61850-3 electrical substation automation
  • Rack-mounted Modbus data concentration for large slave populations up to 247 slaves
  • Converting Modbus RTU/ASCII field devices to Modbus TCP for a SCADA host
  • Six-port Ethernet aggregation with RSTP redundancy in a control room
  • Fibre plant using the six-slot 100Base-FX SFP version
  • Isolated RS-422/485 serial runs using the 3 kV Sis variant

Complete the stack

Products that work with this one — connect it, power it, and get it online.

MB5908A-CT — frequently asked questions

Is this model suitable for an electrical substation?

Yes. It is IEC 61850-3 certified and its EMC listing includes IEC 61850-3 / IEEE 1613, with safety to EN61010-1 and EN 61010-2-201, so it can be set up into IEC 61850-3 substations.

What does the CT concentrator add over a plain gateway?

The Modbus Data Concentrator runs pre-defined Modbus commands to read and write slave data via the serial ports and mirrors that data into its own memory, so requesting masters get responses faster. It maps all slaves' data automatically across up to 64 connections.

How many Modbus slaves does it support?

A maximum of 16 Modbus TCP clients and a maximum of 247 slaves.

How many Ethernet interfaces are there?

Six. RJ45 versions provide 6x 10/100BASE-T(X); SFP versions provide 6x 100Base-FX SFP slots. Listed transceivers are AXFD-1314-0523 (155Mbps multi-mode, 2 km) and AXFD-1314-0553 (155Mbps single-mode, 30 km).

What power inputs are available and are they redundant?

Redundant 24-48 VDC, or redundant 100-240 VAC / 100-370 VDC on the HV series, on a 10-pin terminal block. Input current is 0.73 A at 24 VDC, 0.35 A at 100 VAC or 0.20 A at 100 VDC, for approximately 20 W.

How much does the ATOP MB5908A-CT Rugged Serial to Ethernet Modbus Gateway cost in the UK?

The ATOP MB5908A-CT Rugged Serial to Ethernet Modbus Gateway is supplied to order and priced on application. Send a quote request and we confirm the price and lead time in writing, usually the same working day. No account is needed. Indiott is a UK distributor invoicing with VAT (PSI Technologies Ltd, VAT GB 730 2340 83).

What is the lead time and delivery cost for the ATOP MB5908A-CT Rugged Serial to Ethernet Modbus Gateway?

The ATOP MB5908A-CT Rugged Serial to Ethernet Modbus Gateway is supplied to order. We confirm the lead time in writing with your quote, before you commit to anything. UK delivery is a flat £14.25 per order ex VAT, whatever the weight or how many items you order. We ship to GB and the EU and provide a VAT invoice with every order.