ATOP PG5908 Smart Grid Protocol Gateway (IEC 61850)
Request a price
The ATOP PG5908 is a rack-mount smart-grid protocol gateway with eight RS-232/422/485 serial ports on RJ45 connectors (optional 2.5 kV isolation) and two 10/100BASE-T(X) Ethernet ports with RSTP. It offers all 48 of ATOP's Modbus, DNP3, IEC 60870-5-101/103/104 and IEC 61850 licence pairs, runs from 24-48 VDC or 100-240 VAC, and operates from -20°C to +70°C.
Serial Ports8 × RS-232/422/485 on RJ45, optional 2.5 kV isolation
● Quotes answered within one working day
Available to order · request a quote for price and lead time
Delivery & assurance
- Ships from the UK
- UK & EU delivery, quoted with your price
- Pay by card or invoice
- Manufacturer's warranty
Questions about this product? Call our UK team: 023 9223 3611
Description
The PG5908 Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different protocols Ethernet or Serial based. The serial devices communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.
8-Port RS‑232/485/422 with RJ45 and 2× Fast Ethernet protocol gateway. Supports DNP3, Modbus, IEC 60870‑5‑101/103/104 and IEC 61850.
PG5908 specifications
| RJ45 Ports | 2 × 10/100BASE-T(X) |
|---|---|
| Redundancy Protocols | RSTP on both Ethernet ports |
| Serial Ports | 8 × RS-232/422/485 (full function) |
| Serial Interface | RJ45 serial connectors |
| Serial Isolation | 2.5 kV (optional) |
| Protocols | Modbus RTU/ASCII, Modbus TCP, DNP3 serial and TCP/IP, IEC 60870-5-101, IEC 60870-5-103 (master), IEC 60870-5-104, IEC 61850 |
| Front-End Protocols (Slave/Server) | Modbus RTU/ASCII slave, Modbus TCP server, DNP3 serial slave, DNP3 TCP/IP server, IEC 60870-5-101 slave, IEC 60870-5-104 server, IEC 61850 server |
| Back-End Protocols (Master/Client) | Modbus master (serial) or client (TCP), DNP3 master (serial) or client (TCP/IP), IEC 60870-5-101 master, IEC 60870-5-103 master, IEC 60870-5-104 client, IEC 61850 client |
| Licence Combinations | All 48 pairs in ATOP's software table, including serial-to-serial (e.g. MBSS-DNSM, DNSS-01SM); optional full licence for concurrent multi-protocol conversion |
| Modbus | RTU/ASCII (serial) and TCP; up to 64 slaves/servers; up to 8000 points read and 4000 commands written; function codes 1, 2, 3, 4, 5, 6, 15, 16 and 43 (server side) |
| DNP3 | Level 2 and a subset of Level 3 (IEEE 1815-2012 Level 2); serial or TCP/UDP; server serves up to 5 TCP clients; client polls up to 16 IEDs; up to 8000 binary inputs, 2000 binary outputs, 4000 double inputs, 250 analogue inputs, 250 analogue outputs, 250 counters |
| IEC 60870-5-104 | Edition 2; server serves up to 5 clients; client polls up to 10 IEDs; up to 1000 monitor points and 500 control points per data type; server event buffer up to 20,000 events |
| IEC 61850 | Client and server, Edition 1 and Edition 2, MMS (IEC 61850-8-1); 8 logical devices per port; direct and SBO control with normal or enhanced security |
| VPN | Supported |
| Time Synchronisation | Protocol clock synchronisation over IEC 61850, DNP3 and IEC 60870-5-101/103/104; CP56Time2a timestamps on IEC 60870-5-104 |
| Configuration | Web interface for network settings; eNode Designer for serial settings, protocol parameters and data point mapping |
| Input Voltage | 24-48 VDC or 100-240 VAC |
| Power Redundancy | 1 power input |
| Mounting | Rack mount |
| Ingress Protection | IP30 |
| Operating Temperature | -20°C to +70°C |
| Certifications | CE (EN 61000-6-2, EN 61000-6-4), FCC Part 15 Subpart B Class A, EN 60950-1; industrial EMC protection |
Specifications taken from the manufacturer datasheet.
Which version do I need?
PG5908 hardware: 8 serial ports on RJ45 connectors with optional 2.5 kV isolation, and 24-48 VDC or 100-240 VAC power. The protocol function is a separate software licence from ATOP's table, written front-end then back-end: the front-end is the slave or server that your SCADA, RTU or PLC master talks to, and the back-end is the master or client the gateway uses to poll field devices. For example, PG5908 with 04ES-03SM presents an IEC 60870-5-104 server to the control centre and polls IEC 60870-5-103 protection relays on the serial ports as master; 50ES-MBSM presents an IEC 61850 server to the station bus and polls Modbus RTU devices as master. All 48 licences in the table are offered, including serial-to-serial pairs. An optional full licence runs one or more protocols concurrently on both sides instead of a single pair. If the site needs IEC 61850-3 / IEEE 1613, fibre, TB5/DB9 serial connectors or -40°C operation, choose the PG5908A instead.
Typical applications for the PG5908
- Concentrating up to 8 serial IEDs into an IEC 61850 station bus (50ES-MBSM)
- Collecting IEC 60870-5-103 protection relay data for an IEC 60870-5-104 SCADA (04ES-03SM)
- Serial-to-serial conversion between a legacy master and outstations, e.g. Modbus RTU slave to DNP3 serial master (MBSS-DNSM)
- Control-room and relay-room racks in power generation plants
- Oil and gas and manufacturing sites with many legacy serial devices
- Structured-cabling serial runs using RJ45 serial ports
Complete the stack
Products that work with this one — connect it, power it, and get it online.
PG5908 — frequently asked questions
What ports does the PG5908 have?
8 full-function RS-232/422/485 serial ports on RJ45 connectors, with optional 2.5 kV isolation, and 2 × 10/100BASE-T(X) RJ45 Ethernet ports that support RSTP.
What is the difference between the PG5908 and the PG5908A?
The PG5908A is ticked for IEC 61850-3 / IEEE 1613 in ATOP's guide, has 6 Fast Ethernet ports (RJ45 or SFP) instead of 2, TB5 or DB9 serial connectors with optional 3 kV isolation, two power inputs including 100-370 VDC, two relay outputs and a -40°C to +85°C rating. The PG5908 uses RJ45 serial connectors, a single 24-48 VDC or 100-240 VAC input and is rated -20°C to +70°C.
Which protocol conversions are available?
All 48 front-end/back-end licences in ATOP's table, across Modbus RTU/ASCII and TCP, DNP3 serial and TCP/IP, IEC 60870-5-101, IEC 60870-5-103 (master), IEC 60870-5-104 and IEC 61850, including serial-to-serial pairs. An optional full licence runs several protocols concurrently.
How is it powered?
From 24-48 VDC or 100-240 VAC on a single power input.
What temperature range and approvals apply?
-20°C to +70°C operation in an IP30 rack-mount housing. ATOP's guide lists CE (EN 61000-6-2/-6-4), FCC Part 15 Subpart B Class A and EN 60950-1, with industrial EMC protection.
How many devices can it poll per protocol?
Up to 64 Modbus slaves or servers (8000 read points, 4000 write commands), up to 16 DNP3 IEDs, and up to 10 IEC 60870-5-104 IEDs; as a DNP3 or IEC 104 server it serves up to 5 clients, with a 20,000-event IEC 104 buffer.
How much does the ATOP PG5908 Smart Grid Protocol Gateway (IEC 61850) cost in the UK?
The ATOP PG5908 Smart Grid Protocol Gateway (IEC 61850) is supplied to order and priced on application. Send a quote request and we confirm the price and lead time in writing, usually the same working day. No account is needed. Indiott is a UK distributor invoicing with VAT (PSI Technologies Ltd, VAT GB 730 2340 83).
What is the lead time and delivery cost for the ATOP PG5908 Smart Grid Protocol Gateway (IEC 61850)?
The ATOP PG5908 Smart Grid Protocol Gateway (IEC 61850) is supplied to order. We confirm the lead time in writing with your quote, before you commit to anything. UK delivery is a flat £14.25 per order ex VAT, whatever the weight or how many items you order. We ship to GB and the EU and provide a VAT invoice with every order.