UK industrial technology since 1998 Authorised Milesight distributor Ships from the UK
TS602-L0DEU

Milesight TS602 Cellular Temperature Sensor

Authorised Milesight UK Distributor
In stock UKMilesight
Where it sits in the stack

£89.78 ex VAT (£107.74 inc. VAT)

Cellular (LTE Cat.1) temperature sensor with external M12 probe (PT100 / DS18B20 options)

TS602 is a cellular (LTE Cat.1) temperature and humidity sensor for cold-chain monitoring. Its decisive spec is the 5-pin M12 A-coded male connector for an external PT100, DS18B20 or TH probe, so the measuring range depends on the probe: -200°C to 50°C on the low-temperature probe, -50°C to 500°C on the industrial probe. The TS602 also has a 0.96-inch OLED display.

Connector Type / Number5-pin M12 A-Coded Male Connector — 1 × connector for an external TH / DS18B20 / PT100 probe (the TS601 has no connector and uses a built-in sensor)

Add to quote

In stock · typically dispatched within 14 working days from the UK

Quotes answered within one working day · UK support

Delivery & assurance

  • Ships from the UK
  • £14.25 flat UK delivery
  • Secure checkout — card, Klarna, invoice
  • Manufacturer's warranty

Ships to the UK & EU · VAT invoice provided · Delivery & returns

Questions about this product? Call our UK team: 023 9223 3611

Solutions this product serves

Description

The TS602 is a Milesight cellular temperature sensor — cellular (LTE Cat.1) temperature sensor with external M12 probe (PT100 / DS18B20 options).

Key features

  • Cellular (LTE Cat.1) temperature sensor with external M12 probe (PT100 / DS18B20 options)
  • Wide measuring range from -200C to +500C depending on probe
  • 0.96-inch OLED display for real-time on-device readings
  • Approx. 4.2 years battery life on replaceable cell
  • Cold-chain and industrial temperature monitoring with interchangeable probes

Supplied by Indiott, the UK industrial IoT specialists, with engineer-led support. Request a quote for pricing, stock and lead times.

Additional information

Weight 0.2 kg

TS602-L0DEU specifications

Connector Type5-pin M12 A-Coded Male Connector
Connector Number1 × Connector for TH/DS18B20/PT100 Sensor
Temperature / Humidity sensingRefer to Optional Sensors — measurement is made by the external probe (the TS601 uses a built-in Digital CMOSens® MEMS sensor)
Optional PT100 probesRegular SP11-B05-125-200: -40°C ~ 125°C, Class B, ±0.5°C (-40°C~40°C) / ±1°C (40°C~125°C). Food Applications SP11-AF10-125-150: -40°C ~ 125°C, Class A, ±0.4°C. Low Temperature SP11-A03-050-150: -200°C ~ 50°C, Class A. Industrial SP11-A05-500-150: -50°C ~ 500°C, Class A
Optional DS18B20 probeSP12-125-150: -40°C ~ 125°C, ±0.5°C (-10°C~85°C), ±2°C (-40°C~-10°C, 85°C~125°C); drift Typ. ±0.2°C
Optional TH probeSP13-125-150: Temperature -40°C ~ 125°C (±0.3/±0.2/±0.5°C by band); Humidity 0% RH ~ 100% RH, ±2% RH; drift Typ. 0.03°C/year
Screen0.96-inch OLED (TS601: none — it has a status LED instead)
LightRange 0 to 600 Lux; Status Light/Dark (cargo box opening detection)
Device PositionStatus Normal/Tilt; Measurement Range -90° to +90° on all X, Y, Z axes (3-axis accelerometer)
Base Station PositioningLongitude/Latitude; on urban main roads Typ. Deviation 1 km, Max Deviation 5 km
Wireless TechnologyLTE Cat.1
FrequencyLTE-FDD: B1/B3/B5/B7/B8/B20/B28 for EMEA+Australia/New Zealand
SIM Slot1 × Nano SIM (4FF) Slot, 1.8V/3V
Application ModeTCP/UDP/MQTT/AWS/Milesight Development Platform
Min. Packet Transmission Interval30 min @ Operating Temperature ≤ 0°C; 15 min @ Operating Temperature > 0°C
Advanced FeaturesThreshold Alarm, Data Storage (5,000 entries), Data Retransmission
Power Supply2 × 2500 mAh CR18505 Li-MnO2 Batteries
Battery Life (6 reports/day, 8 packages per report, 30-min collection interval, positioning disabled, -20°C)MQTT/TCP - Around 4.2 Years; AWS - Around 3.5 Years; UDP - Around 4.6 Years
Operating Temperature / Humidity / IP-35°C to 70°C; 0% - 95% RH (non-condensing); IP67
Housing / Weight / DimensionABS+PC (Food-grade), White; 200g with batteries; 112 × 72 × 29 mm

Specifications taken from the manufacturer datasheet.

Which version do I need?

The datasheet does not decode SKU suffixes such as -L0DEU. It documents a single cellular band set — LTE-FDD B1/B3/B5/B7/B8/B20/B28 for EMEA plus Australia/New Zealand — which covers the UK; because the TS602 is cellular there is no LoRaWAN frequency choice (no EU868 variant), but a Nano SIM (4FF) is required. Probes are separate order codes: PT100 SP11-B05-125-200 / SP11-AF10-125-150 / SP11-A03-050-150 / SP11-A05-500-150, DS18B20 SP12-125-150, and TH SP13-125-150. Optional magnetic mounting is listed alongside cable-tie, 3M tape and wall screw mounting.

Typical applications for the TS602-L0DEU

  • Cold chain transportation of food
  • Cold chain transportation of medicine
  • Temperature and humidity monitoring in harsh environments
  • Cargo box opening detection and alarm via the light sensor
  • Asset tracking using base station positioning
  • Industrial and low-temperature process measurement using PT100 probes

Complete the stack

Products that work with this one — connect it, power it, and get it online.

TS602-L0DEU — frequently asked questions

Which probes can I connect to the TS602?

Four PT100 probes (SP11-B05-125-200 regular -40°C~125°C Class B; SP11-AF10-125-150 food-grade 316 stainless needle -40°C~125°C Class A ±0.4°C; SP11-A03-050-150 low temperature -200°C~50°C; SP11-A05-500-150 industrial -50°C~500°C), a DS18B20 probe (SP12-125-150, -40°C~125°C) and a TH temperature-humidity probe (SP13-125-150, -40°C~125°C and 0~100% RH).

Does the TS602 need a LoRaWAN gateway?

No. It is cellular — LTE Cat.1 with a 1.8V/3V Nano SIM (4FF) slot on LTE-FDD bands B1/B3/B5/B7/B8/B20/B28 for EMEA plus Australia/New Zealand — and reports via TCP, UDP, MQTT, AWS or the Milesight Development Platform.

How does the TS602 differ from the TS601?

The TS601 has a built-in Digital CMOSens® sensor and a status LED indicator. The TS602 has no LED; instead it carries a 0.96-inch OLED display and a 5-pin M12 A-coded male connector for an external TH, DS18B20 or PT100 probe, so its range and accuracy are set by the probe chosen.

How often can the TS602 report?

The minimum packet transmission interval is 30 minutes at operating temperatures at or below 0°C and 15 minutes above 0°C, where packet transmission interval = reporting interval × cumulative numbers. It stores 5,000 entries locally and supports data retransmission so readings are not lost when coverage drops.

Is the TS602 suitable for food and pharmaceutical loads?

The enclosure is food-grade ABS+PC and rated IP67, allowing safe contact with food or medicines, and the food-application PT100 probe (SP11-AF10-125-150) is a 316 food-grade stainless steel needle on a food-grade silicone cable rated -60°C~250°C.

How much does the Milesight TS602 Cellular Temperature Sensor cost in the UK?

The Milesight TS602 Cellular Temperature Sensor is £89.78 ex VAT from Indiott, a UK distributor. The price is published rather than quote-only, and we invoice with VAT (PSI Technologies Ltd, VAT GB 730 2340 83). UK delivery is a flat £14.25 per order ex VAT, whatever the weight.

What is the lead time and delivery cost for the Milesight TS602 Cellular Temperature Sensor?

The Milesight TS602 Cellular Temperature Sensor is in stock and typically dispatched within 14 working days from the UK. UK delivery is a flat £14.25 per order ex VAT, whatever the weight or how many items you order. We ship to GB and the EU and provide a VAT invoice with every order.

£89.78 ex VATBuy now