Priced kit · Buildings and estates
Door sensors, frost and damp sensors and a leak sensor on a 4G gateway, for a building with nobody in it and no broadband. 7 parts for £408.49 ex VAT.
| Part | What it does here | Qty | Line ex VAT |
|---|---|---|---|
UG63 mini LoRaWAN gateway with 4GUG63-L08GL-868M · £131.68 eachGateway with 4G built in, since an empty building rarely has a working network. Needs mains power and a SIM.
|
Gateway with 4G built in, since an empty building rarely has a working network. Needs mains power and a SIM. | 1 | £131.68 |
EM300-MCS door sensor, IP67EM300-MCS-868M · £52.37 eachFront, rear and one internal door. IP67 for a cold, damp building, and each logs temperature and humidity.
|
Front, rear and one internal door. IP67 for a cold, damp building, and each logs temperature and humidity. | 3 | £157.11 |
EM300-TH temperature and humidity sensorEM300-TH-868M · £38.90 eachThe coldest room and the room with the boiler or water tank, for frost risk and damp.
|
The coldest room and the room with the boiler or water tank, for frost risk and damp. | 2 | £77.80 |
WS303 mini leak sensorWS303-868M · £41.90 eachOn the floor under the stopcock or boiler. Triggers at 0.5 mm of water and sounds a buzzer.
|
On the floor under the stopcock or boiler. Triggers at 0.5 mm of water and sounds a buzzer. | 1 | £41.90 |
| Parts | £408.49 | ||
| UK delivery, one flat charge per order | £14.25 | ||
| Total ex VAT | £422.74 | ||
Prices are read from the shop each time this page loads and exclude VAT. Every part is also sold on its own, so you can change any quantity once the kit is in your basket.
Empty buildings fail quietly. A door forced at the back, a boiler that stops in a cold snap, a slow leak from a pipe that froze: each costs far more when it is found on the next inspection rather than the day it happens. This kit reports all three and keeps a dated record of the building's condition between visits.
Vacant buildings rarely have broadband, so the gateway has 4G built in. It does need mains power and a SIM.
Only your insurer can say. Many policies require regular physical inspections of unoccupied buildings whatever monitoring is fitted. The kit gives you a dated record of doors, temperatures and leaks between those visits, which is worth sharing with them.
The gateway stops sending alerts until power returns. The sensors keep recording on their own storage and send the missed readings afterwards, so you still see what happened.
An empty building gets cold and damp. The EM300-MCS is sealed to IP67 and rated from -30°C to 70°C, where the indoor WS301 is IP20 and rated for non-condensing air.
Yes. Unscrew or unstick the sensors, and the gateway and sensors keep their configuration.