Priced kit · Buildings and estates
Flow and return temperatures, the boiler fault contact, the room itself and a leak sensor, for a plant room that has no building management system. 6 parts for £317.22 ex VAT.
| Part | What it does here | Qty | Line ex VAT |
|---|---|---|---|
UG63 mini LoRaWAN gatewayUG63-868M · £98.76 eachGateway for the plant room devices, on Ethernet or the 4G version.
|
Gateway for the plant room devices, on Ethernet or the 4G version. | 1 | £98.76 |
EM300-TH temperature and humidity sensorEM300-TH-868M · £38.90 eachRoom temperature and humidity. A cold plant room is a frost risk; a hot one is a ventilation fault.
|
Room temperature and humidity. A cold plant room is a frost risk; a hot one is a ventilation fault. | 1 | £38.90 |
TS201 temperature sensor with probeTS201-868M · £44.89 eachProbes strapped to the flow and return pipes under the insulation, to see heat actually leaving the plant.
|
Probes strapped to the flow and return pipes under the insulation, to see heat actually leaving the plant. | 2 | £89.78 |
EM300-DI pulse counter and digital inputEM300-DI-868M · £47.88 eachIn digital input mode on the boiler or pump panel's volt-free fault contact, so a lockout raises an alert.
|
In digital input mode on the boiler or pump panel's volt-free fault contact, so a lockout raises an alert. | 1 | £47.88 |
WS303 mini leak sensorWS303-868M · £41.90 eachOn the floor under the pressurisation unit or the lowest valve.
|
On the floor under the pressurisation unit or the lowest valve. | 1 | £41.90 |
| Parts | £317.22 | ||
| UK delivery, one flat charge per order | £14.25 | ||
| Total ex VAT | £331.47 | ||
Prices are read from the shop each time this page loads and exclude VAT. Every part is also sold on its own, so you can change any quantity once the kit is in your basket.
Small buildings rarely have a BMS, so a boiler lockout is discovered when the radiators go cold. This kit watches the plant room the way an engineer would on a visit: is heat leaving the plant, is the plant reporting a fault, is the room itself too cold or too hot, and is water on the floor.
The EM300-DI reads the volt-free fault contact most boilers and pump panels provide, so a lockout becomes an alert rather than a phone call from a cold building.
No. A BMS controls plant as well as monitoring it. This kit gives a building without one the alerts that matter most: faults, lost heat, frost risk and leaks.
Many domestic-scale boilers do not. In that case the flow and return probes still show when the boiler stops delivering heat, which is the symptom that matters.
Not the TS201 probe, which is designed to be clamped or inserted into air and liquids through a gland. For immersion in a pocket, look at the TS101 insertion sensor.
Yes. Flow and return temperatures matter even more for a heat pump, because the gap between them shows whether it is running efficiently.